Limit on New Superbasics
- Type
Integer
- Range
{0 .. Maxint}
- Default
0
When there has been a sufficient reduction in the reduced gradient in one subspace new non-basics can be selected to enter the superbasis. The ones with largest reduced gradient of proper sign are selected, up to a limit.
If the value of this option is positive then the limit is min(500,value).